The DECT Radio Network Repeater (DECT RNR) is an extension of
a wireless RS232 data radio connection. The DECT RNR is
based on the DECT Engine MD32 Data Radio Module from Siemens AG.
With a RNR the range between a FixedPart and a PortablePart can be extended on
approx. 600 m /1968.50 ft in the open area and approx. 100 m /
328.08 ft in buildings. The transmission rate is 115,2 kBit/s.
The RNR consists of two Siemens DECT Engine MD32 Modules. One
module was configurated as a PP to a RNR-PP The other one as a FP to RNR-FP. The
RNR transmits the control lines RTS/CTS and the data lines TxD and RxD.
The device has a serial interface for configuration, an
internal aerial and an external power supply. The Case
is made of shockproof polystyrol (light grey/dark grey). Measurements: (H x W x D):
125 x 67 x 32 mm. A hanger for wall
assembly is optionally
available. The DECT RNR
can be practised with a temperature of 0°C - 40°C.
Construction

A DECT connection consists of a fixed part (FP) and a
portable part (PP). 16 PP`s belong to 1 FP. The 16 PP`s are connected to each
other as a group by a log-in procedure.Now
a data connection can be made between FP and PP. The
group also stays intact during a loss of voltage. In our applications we use the
DECT Engine MD3x by Siemens AG.
MD 32 is the classical DECT
Engine for the wireless
connection via
radio of RS232 interfaces. The maximum
rate of data transfer is 115,2 Kbit/s. The point to point configuration has in
many devices substituted Cable, IrDa or analogue radio standards.With
the high-quality server-mode new
point-off sales applications were able to be created
for new ideas.
Three operational modes can be set:
V.24 Replacement PP
(Portable Part)
V.24 Replacement FP (Fixed Part)
V.24 Server FP (Fixed Part)
For a point-to-point data transmission
one module must be configured as a terminal device (V.24 Replacement PP,
portable part), and a second as a basis station (V.24 Replacement FP, fixed
part).
-
Configuration of the module over AT
commands
-
Four different configurations are
storable
-
The terminal device can log itself
onto six basis stations
-
The logging-on of up to 16 terminal
devices onto one basis station is possible
-
The basis station configured as a
V.24 Server FP can serve up to 16 RS232 connections of which 4 can be
simultaneously active
-
Automatic setting-up and dismantling
of the connection is dependent on data traffic
-
Internal error correction protocol
guarantees a bit error rate of < 10^-8
-
Certified according to the
DECT-Standard CTR6
-
Secure data transmission over a reserved frequency band, data saving protocol
(LU10 Standard) as well as data encryption
|