DECT Plug A2
The DECT Plug A2 is a cordless RS232
data radio connection.
For the radio link
the
DECT Engine MD32
Data
Radio
Module
by
Siemens
is integrated.
The range of the DECT Plug A2
is in the open area approx. 300m/ 984,25 ft and in buildings
approx. 50m / 164,04ft. It has 2 internal aerials,
a
serial interface
and an
external power supply. The Case
consists of shockproof
polystyrol (light grey/dark grey). Measurements: (H x W x D):
125 x 67 x 32 mm. A hanger for the wall
mounting is optionally
available. The DECT Plug A2 can run at a temperature of
0°C - 40°C and has the following settings:
-
Transmission rate 19,2 until
115,2 kBit/s
-
Xon
/ Xoff or CTS / RTS Protocol
-
8 Bit, 1 Stopbit, no Parity.
A DECT connection consists of a fixed
part (FP) and a portable part (PP). 16 PP`s belong to 1 FP. The 16 PP`s are
connected to each other as a group by a log-in procedure. After this a data
connection can be made between FP and PP. The cluster
also stays intact during a loss of voltage. In our applications we use the DECT
Engine MD3x by Siemens
AG:
MD 32 is the classical DECT
Engine for the wireless connection over radio of RS232 interfaces. The maximum
rate of data transfer is 115,2 Kbit/s. The point-to.point
configuration has substituted cable, IrDa or analogue radio standards in
many applications.With the
ambitious server mode new ’point-off sales’ applications were able to be created
for new product ideas.
Three operating modes can be set:
V.24 Replacement PP
(Portable Part)
V.24 Replacement FP (Fixed Part)
V.24 Server FP (Fixed Part)
For a point-to-point data transmission
one module must be configured as a terminal device (V.24 Replacement PP,
portable part), and a second as a basis station (V.24 Replacement FP, fixed
part).
-
Configuration of the module over AT
commands
-
Four different configurations are
storable
-
The terminal device can log itself
onto six basis stations
-
The logging-on of up to 16 terminal
devices onto one basis station is possible
-
The basis station configured as a
V.24 Server FP can serve up to 16 RS232 connections of which 4 can be
simultaneously active
-
Automatic setting-up and dismantling
of the connection is dependent on data traffic
-
Internal error correction protocol
guarantees a bit error rate of < 10^-8
-
Certified according to the
DECT-Standard CTR6
-
Secure data transmission over a reserved frequency band, data saving protocol
(LU10 Standard) as well as data encryption
|